DATE: March 1, 2011
TO: Norene Lind, Regulatory Affairs Manager
State Office of Administrative Hearings and Rules
FROM: Deborah Young, Director
Bureau of Construction Codes, Office of Administrative Services
SUBJECT: Request for correction of the Part 10, Michigan Uniform Energy Code R 408.31065, pursuant to Administrative Procedures Act, Section 56(1), MCL
24.256 (1).
DATE: 2010 MR 21, Eff. March 9, 2011.
The Bureau of Construction Codes, as a promulgating agency, is writing to request that the State Office of Administrative Hearings and Rules exercise its discretion to correct an obvious error in the Part 10, Michigan Uniform Energy Code Rules as published in the Michigan Administrative Code.
The error is contained in R 408.31065. The rule was promulgated as part of the revisions to the Part 10, Michigan Uniform Energy Code, 2010 MR 21, Eff. March 9, 2011.
The agency adopted the 2009 version of the International Energy Conservation Code, amending Table 402.1.3 to reflect only Michigan specific equivalent U-factors. When the Table was typed for inclusion as the Michigan rule the anchor of footnote “a” was inadvertently left from the table title.
The affected Table currently reads (italics added):
Table 402.1.3 Equivalent U-Factors
Climate Zone
Fenestration
U -Factor
Skylight
U -Factor
Ceiling
U-Factor
Frame Wall
U -Factor
Mass wall
U -Factor b
Floor
U -Factor
Basement Wall
U -Factor d
Crawl Space Wall
U -Factor c
5A
0.35
0.60
0.030
0.057
0.082
0.033
0.059
0.065
6A
0.35
0.60
0.026
0.057
0.060
0.033
0.050
0.065
7
0.35
0.60
0.026
0.057
0.057
0.026
0.050
0.065
a. Nonfenestration U-factors shall be obtained from measurement, calculation, or an approved source.
b. When more than half the insulation is on the interior, the mass wall U-factors shall be the same as the frame wall
U-factor in Zones 5 to 7.
c. Basement wall U-factor requirements shown in Table 402.1.3 include wall construction and interior air films, but exclude soil conductivity and exterior air films.
d. Foundation U-factor requirements shown in Table 402.1.3 include wall construction and interior air films, but exclude soil conductivity and exterior air films. U-factors for determining code compliance in accordance with
section 402.1.4 (total UA alternative ) of section 405 (simulated performance alternative) shall be modified to include soil conductivity and exterior air films.
The language should read:
Table 402.1.3 Equivalent U-Factorsa
Climate Zone
Fenestration
U -Factor
Skylight
U -Factor
Ceiling
U-Factor
Frame Wall
U -Factor
Mass wall
U -Factor b
Floor
U -Factor
Basement Wall
U -Factor d
Crawl Space Wall
U -Factor c
5A
0.35
0.60
0.030
0.057
0.082
0.033
0.059
0.065
6A
0.35
0.60
0.026
0.057
0.060
0.033
0.050
0.065
7
0.35
0.60
0.026
0.057
0.057
0.026
0.050
0.065
a. Nonfenestration U-factors shall be obtained from measurement, calculation, or an approved source.
b. When more than half the insulation is on the interior, the mass wall U-factors shall be the same as the frame wall
U-factor in Zones 5 to 7.
c. Basement wall U-factor requirements shown in Table 402.1.3 include wall construction and interior air films, but exclude soil conductivity and exterior air films.
d. Foundation U-factor requirements shown in Table 402.1.3 include wall construction and interior air films, but exclude soil conductivity and exterior air films. U-factors for determining code compliance in accordance with section 402.1.4 (total UA alternative ) of section 405 (simulated performance alternative) shall be modified to include soil conductivity and exterior air films.
If you have any questions about this transmittal, you may contact me at 517.335.2626. cc: Agency Liaison, Shannon Matsumoto
March 4, 2011
Ms. Deborah Young
Michigan Department of Energy, Labor & Economic Growth Bureau of Construction Codes
PO Box 30255
Lansing, MI 48909
RE: Request for correction under MCL 24.256(1) - Dear Ms. Young:
The State Office of Administrative Hearings and Rules hereby approves your request to amend the Michigan Administrative Code under MCL 24.256(1) of the Administrative Procedures Act.
Table 402.1.3 within R 408.31065 will be amended to read as follows:
Table 402.1.3 Equivalent U-Factorsa
Climate Zone
Fenestration
U -Factor
Skylight
U -Factor
Ceiling
U-Factor
Frame Wall
U -Factor
Mass wall
U -Factor b
Floor
U -Factor
Basement Wall
U -Factor d
Crawl Space Wall
U -Factor c
5A
0.35
0.60
0.030
0.057
0.082
0.033
0.059
0.065
6A
0.35
0.60
0.026
0.057
0.060
0.033
0.050
0.065
7
0.35
0.60
0.026
0.057
0.057
0.026
0.050
0.065
a. Nonfenestration U-factors shall be obtained from measurement, calculation, or an approved source.
b. When more than half the insulation is on the interior, the mass wall U-factors shall be the same as the frame wall U-factor in Zones 5 to 7.
c. Basement wall U-factor requirements shown in Table 402.1.3 include wall construction and interior air films, but exclude soil conductivity and exterior air films.
d. Foundation U-factor requirements shown in Table 402.1.3 include wall construction and interior air films, but exclude soil conductivity and exterior air films. U-factors for determining code compliance in accordance with section 402.1.4 (total UA alternative ) of section 405 (simulated performance alternative) shall be modified to include soil conductivity and exterior air films.
MEMORANDUM
DATE: March 1, 2011
TO: Norene Lind, Regulatory Affairs Manager
State Office of Administrative Hearings and Rules
FROM: Deborah Young, Director
Bureau of Construction Code, Office of Administrative Services
SUBJECT: Request for correction of the Part 10, Michigan Uniform Energy Code R 408.31060e, pursuant to Administrative Procedures Act, Section 56(1), MCL
24.256 (1).
DATE: 2010 MR 21, Eff. March 9, 2011.
The Bureau of Construction Codes, as a promulgating agency, is writing to request that the State Office of Administrative Hearings and Rules exercise its discretion to correct an obvious error in the Part 10, Michigan Uniform Energy Code Rules as published in the Michigan Administrative Code.
The error is contained in R 408.31060e. The rule was promulgated as part of the revisions to the Part 10, Michigan Uniform Energy Code, 2010 MR 21, Eff. March 9, 2011.
The agency adopted the 2009 version of the International Energy Conversation Code, amending Table 301.3(2) to reflect only Michigan specific climate zones. When the Table was typed for inclusion as the Michigan rule the SI Units column Heating Degree Days (HDD) were incorrectly listed as Farenheit (F). This Table corresponds with Table 301.3(1), which defines the major climate types. SI Units are a metric measurement. Showing these measurements as Farenheit will create conflict and result in incorrect thermal measurements when calculating the proper insulation to be used in residential structures.
The affected Table currently reads:
Table 301.3(2) Climate Zone Definitions
Zone Number
Thermal Criteria
IP Units
SI Units
5A
5400 < HDD65°F£7200
3000 < HDD18°F£4000
6A
7200 < HDD65°F£9000
4000 < HDD18°F£5000
7
9000 < HDD65°F£12600
5000 < HDD18°F£7000
For SI: ºC = [(ºF)-32]/1.8
The language should read:
Table 301.3(2) Climate Zone Definitions
Zone Number
Thermal Criteria
IP Units
SI Units
5A
5400 < HDD65°F£7200
3000 < HDD18°C£4000
6A
7200 < HDD65°F£9000
4000 < HDD18°C£5000
7
9000 < HDD65°F£12600
5000 < HDD18°C£7000
For SI: ºC = [(ºF)-32]/1.8
If you have any questions about this transmittal, you may contact me at 517.335.2626.
March 4, 2011
Ms. Deborah Young
Michigan Department of Energy, Labor & Economic Growth Bureau of Construction Codes
PO Box 30255
Lansing, MI 48909
RE: Request for correction under MCL 24.256(1) Dear Ms. Young:
The State Office of Administrative Hearings and Rules hereby approves your request to amend the Michigan Administrative Code under MCL 24.256(1) of the Administrative Procedures Act.
Table 301.3(2) in R 408.31060e will be amended to read:
Table 301.3(2) Climate Zone Definitions
Zone Number
Thermal Criteria
IP Units
SI Units
5A
5400 < HDD65°F£7200
3000 < HDD18°C£4000
6A
7200 < HDD65°F£9000
4000 < HDD18°C£5000
7
9000 < HDD65°F£12600
5000 < HDD18°C£7000
For SI: ºC = [(ºF)-32]/1.8