Section 400.11213. Exit doors and stairways.  


Latest version.

All data is extracted from pdf, click here to view the pdf.

  • (1) A required exit door shall be a side-hinged, swing door only. In new construction, additions and conversions, an exit door shall not be less than 36 inches wide. A door forming part of a means of  egress   where door hardware is used shall be of a type that is  nonlocking-against-egress and operable with a single motion.  The use of hooks and eyes,  bolts,  bars, and similar devices is prohibited.

    (2)   A door that forms a part of a means of egress shall swing in the direction of egress for occupancies of 13 or more.

    (3)     In   new  construction,  additions,  conversions,  renovations,  and remodeling, an exit door that is required to swing out shall swing directly onto a floor-level landing that is at least as deep as the swing of the door before the start of any steps or ramps to grade.

    (4)   An exterior wall of a building which has an outside stairway that is used as a required means of egress shall not have windows, vents, or other openings within an area of 6 feet from the stairway, except for either of the following:

    (a)   Windows that are constructed of wired glass and are not openable.

    (b)   Doorways that are used for egress only and are smoke tight.

    (5)   Interior convenience stairways shall be provided with a minimum 1 3/4-inch solid wood core door equipped with positive  self-latching  hardware and a self-closing

    device. All vertical openings, such as stairways, transfer grills, pipes, ducts, and conduit, shall be  sealed with material that is equal to standard partition construction.

    (6)   In new and existing buildings, only ambulatory campers shall be permitted above or below the first or ground floor, except where the floor above or below the first floor provides all required exiting at grade without using stairways.

    (7)   In new construction, additions, conversions, or remodeling, where stairs or steps are used in any part of the required means of egress for camper-occupied areas, they shall have maximum risers of 7 inches and minimum treads of 11 inches. Sturdy and securely fastened guardrails and handrails that are located between 30 and 34 inches, measured vertically, above the nose of the treads shall be provided wherever more than 3 steps are used.