Section 281.3110. Electrical systems.  


Latest version.

All data is extracted from pdf, click here to view the pdf.

  • (1) All electrical systems on a vessel shall be safe and fit for the service intended, shall be in proper operating condition, and shall have a suitable electrical grounding system.

    (2)   Electrical wiring shall be routed as  high  as  possible  above  the bilges, shall be supported in a suitable manner with nonabrasive fasteners to structural members of the  vessel,   and  shall   be    protected   against chafing where passing   through bulkheads or other structural members.Fasteners and protective devices shall not be capable of  causing  damage  to the wiring.

    (3)   Any electrical storage battery or batteries shall be compatible with its attendant electrical system.

    (4)   A battery shall be located so that gas generated in charging is dissipated by natural or mechanical ventilation.

    (5)   A battery shall be accessibly located, provided with suitable supports, and secured against shifting with the motion of the vessel.

    (6)   A battery shall be located in a liquid-tight tray or box of adequate capacity to retain normal spillage or boilover    of     the     electrolyte.     The tray or box shall be

    constructed of, or    lined     with,      suitable     materials resistant to deterioration by the electrolyte.

    (7)   A nonconductive, perforated cover or other suitable  means  shall   be provided to prevent accidental shorting of the battery terminals.