Michigan Administrative Code (Last Updated: November 16, 2016) |
![]() |
Department LR. Licensing and Regulatory Affairs |
![]() |
MIOSHA |
![]() |
Chapter Ionizing Radiation Rules Part 1 to Part 15 |
![]() |
Part 6. INDUSTRIAL RADIOGRAPHIC OPERATIONS AND INSTALLATIONS |
Section 325.5296. Class A installations.
Latest version.
All data is extracted from pdf, click here to view the pdf.
-
(1) Class A installations shall comply with all requirements of rule 294 except for a permissible exposure rate of 7 milliroentgens per hour at any accessible external point.
(2) A personnel monitoring device such as a film badge dosimeter or thermoluminescent dosimeter, shall be permanently assigned to each occupationally exposed individual. This monitoring shall be continuous during employment as a radiation worker.
(3) Personnel exposure records shall be kept on permanent available file at the facility where the exposure occurs for inspection by the department.
(4) Class A approval permits unlimited use at maximum capacity.
History: 1979 AC.