Section 325.5307. Radiation surveys and survey records.  


Latest version.

All data is extracted from pdf, click here to view the pdf.

  • (1) A radiographic operation shall not be conducted unless calibrated and operable radiation survey instrumentation as described in rule 287 is available and used at each site where radiographic exposures are made.

    (2)  A physical radiation survey shall be made after each radiographic exposure utilizing radiographic exposure devices or sealed sources of radioactive material to determine that the sealed source has been returned to its shielded condition.

    (3)   A physical radiation survey shall be made to determine that each sealed source is in its shielded condition before securing the radiographic exposure device or storage container as specified in rule 286. Records shall be kept of these surveys and maintained for inspection by the department.

    (4)  A physical radiation survey shall be conducted to determine  that  the radiation machine is off before each entry into the radiographic   exposure area.

    [Note: The requirements of this rule that pertain  to  radiation  machine registration, licensing, or compliance are under the purview of the Michigan Department of Consumer & Industry Services.]

History: 1979 AC.