Section 336.1357. Coke oven door emissions from coke ovens; doors that are taller than 5 meters.  


Latest version.

All data is extracted from pdf, click here to view the pdf.

  • (1) A person shall not cause or permit to be discharged into the outer air any visible emission from any pushside door, cokeside door, or leveling door serving a coke oven equipped with doors that are taller than 5 meters, with the following exceptions:

    (a)   A visible emission may be emitted from not more than 12% of the total pushside doors on the coke battery.

    (b)   A visible emission may be emitted from not more than 12% of the total cokeside doors on the coke battery.

    (c)   A visible emission may be emitted from not more than 10% of the total leveling doors on the coke battery.

    (2)   A person shall not cause or permit the operation of a coke battery equipped with coke oven doors taller than 5 meters, unless both of the following provisions are met:

    (a)   There is access to a facility to maintain and repair doors and buckstays.

    (b)   An inventory of cleaned and repaired doors is maintained to comply with all of the following:

    (i)   The number of inventoried pushside doors exceeds 5% of the number of pushside doors in service.

    (ii)   The number of inventoried cokeside doors exceeds 5% of the number of cokeside doors in service.

    (iii)    The number of inventoried leveling doors exceeds 5% of the number of leveling doors in service.

    (3)     Compliance with the limits specified in subrule (1) of this rule shall be determined using reference test method 9B.

History: 1980 AACS; 1985 AACS.