Michigan Administrative Code (Last Updated: November 16, 2016) |
Department LR. Licensing and Regulatory Affairs |
Bureau of Fire Services |
Chapter Adult Foster Care Facilities |
Part 6. EXISTING ADULT FOSTER CARE CONGREGATE FACILITIES |
Section 400.18649. Stairways and other vertical openings.
All data is extracted from pdf, click here to view the pdf.
-
(1) In buildings of fire-resistant construction, an interior stairway shall be enclosed with material that has a fire-resistance rating of not less than 1 hour. In buildings of wood joist construction an interior stairway shall be enclosed with material having 1/2-hour-fire-resistance rating. One quarter-inch wired glass in a steel frame meets the 1/2-hour requirement.
(2) An elevator or dumbwaiter shaft shall be completely enclosed by noncombustible materials that have a fire-resistance rating of not less than 1 hour. An opening shall not be allowed through the side wall enclosures for ventilating or other purposes. A door that services an elevator or dumbwaiter shall be of solid construction, be reasonably smoketight when closed, and shall be constructed to resist fire for 1 hour.
Exception: A door in an elevator may have wired glass that is not more than 6 square feet.
History: 1994 AACS.