(1) Dissimilar metals shall be protected from electrolytic action when they are joined.
(2) A metal ladder and appurtenances installed in a corrosive environment shall be coated or otherwise treated to resist corrosion.
(3) A wood ladder subject to deterioration shall be treated with a transparent preservative. Paint shall not be used as a preservative. The design and construction shall prevent or minimize the accumulation of water on or between wood parts.