  • Rule 1276. (1) Spliced welding cable shall not be used  within  10  feet (3.05 m) of an arc welding machine.

    (2)   Equipment in need of repair that constitutes a  safety  hazard  shall not be used or put in use until repairs  are   made  by  a  knowledgeable employee or outside service.

    (3)    Cut insulation on work and lead cable or exposed bare conductors of an arc welding machine shall be protected by electrical tape and made watertight or the conductor shall be replaced. Splices shall be made by insulated welded joints or pressure connectors.

    (4)   An arc welding machine which has become wet  shall   be  thoroughly dried and tested before use.