(1) A counterweight and its pulleys shall be enclosed pursuant to rule 730(2) of the occupational safety standards commission standard, Part 7. Guards for Power Transmission, being R 408.10730(2) of the Michigan Administrative Code.
(2) A counterweight and its pulleys suspended more than 7 feet above the floor or ground, in an area where an employee could walk, shall have an enclosure around the
area of impact or a catch pan under the counterweight of such strength and design to hold the counterweight and pulley from dropping to the ground, floor, or platform.
(3) A counterweight attached to an arm shall have a bolt fastened near the end of the arm or a cable or chain attached to the counterweight to prevent its dropping off the arm.