Rule 416. Section 406.3.6 of the code is amended to read as follows:
406.3.6. Area and height increases. The allowable area and height of open parking garages shall be increased in accordance with the provisions of this section. Garages with sides open on 3/4 of the building perimeter are permitted to be increased by 25% in area and 1 tier in height. Garages with sides open around the entire building perimeter are permitted to be increased 50% in area and 1 tier in height. For a side to be considered open under the provisions of this rule, the total area of openings along the side shall not be less than 50% of the interior area of the side at each tier, and such openings shall be equally distributed along the length of the tier.
Allowable tier areas in table 406.3.5 shall be increased for open parking garages constructed to heights less than the table maximum. The gross tier area of the garage shall not exceed that permitted for the higher structure.
At least 3 sides of each such larger tier shall have continuous horizontal openings not less than 30 inches (762 mm) in clear height extending for at least 80% of the length of the sides, and no part of such larger tier shall be more than 200 feet (60 960mm) horizontally from such an opening. In addition, each such opening shall face a street or yard accessible to a street with a width of at least 30 feet (9144 mm) for the full length of the opening, and standpipes shall be provided in each such tier.
Open parking garages of type II construction, with all sides open, shall be unlimited in allowable area where the height does not exceed 75 feet (22 860 mm). For a side to be considered open, the total area of openings along the side shall not be less than 50% of the interior area of the side at each tier, and such openings shall be equally distributed along the length of the tier. All portions of tiers shall be within 200 feet (60 960 mm) horizontally from such openings.