Section 408.7047. Underground piping.  


Latest version.

All data is extracted from pdf, click here to view the pdf.

  • Rule 47. Section 3.19.5.1 of the ASME A17.1 code is amended to read as follows:

    3.19.5.1 Underground piping in connection with a new hydraulic elevator is prohibited. If a cylinder is replaced on an existing hydraulic elevator, then the corresponding piping, if underground, is prohibited unless  approved by the department.