Rule 62. Section 2.1.1.2 of the ASME A18.1 code is amended to read as follows:
2.1.1.2 The runway entrance shall be guarded at the upper landing by a door of unperforated construction not wider than the platform plus 1 inch (25.4 mm). The door shall be self-closing and guard the entire opening to a height equal to or higher than the height of the platform enclosure. The openings created in the runway by these doors shall provide a minimum vertical clearance of 6 feet 8 inches. The doors shall guard the entire area of the openings except for space necessary for operation. Space necessary for operation shall reject a ball 12 mm (0.5 in.) in diameter. The lift side of the landing doors and sill shall present a smooth surface located not closer than 10 mm (0.375 in.) nor more than 20 mm (0.75 in.) from the platform floor.