Michigan Administrative Code (Last Updated: November 16, 2016) |
![]() |
Department LR. Licensing and Regulatory Affairs |
![]() |
MIOSHA |
![]() |
Chapter Part 6. Fire Exits |
![]() |
Part 6. FIRE EXITS GENERAL PROVISIONS |
Section 408.10636. Maximum travel distance to exits.
Latest version.
All data is extracted from pdf, click here to view the pdf.
-
Rule. 636. Table 1 reads as follows:
TABLE 1
Type of occupancy
Maximum travel distance to exits
(in feet)
Dead-end limits (in feet)
Unsprinkler
ed
Sprinklered
Mercantile, ordinary hazard
150
250
50
Mercantile, high hazard
75
75
0
Business
200
300
50
Industrial
200
250
50
Industrial, high hazard
0
75
0
Storage, low and ordinary hazard
200
400
100
Storage, high hazard
75
100
0
Hotels
100
200
50
Note: For miscellaneous structures, See R 408.10691 to R 408.10697
History: 1979 AC; 1990 AACS; 2015 AACS.