Section 408.30413. Vapor retarders.  


Latest version.

All data is extracted from pdf, click here to view the pdf.

  • Rule 413.  Section 1405.3 of the code is amended to read as follows:

    1405.3. Vapor retarders. Class I or II vapor retarders shall be provided on the interior side of frame walls in zones 5, 6, 7, 8 and marine 4.

    Exceptions:

    1.      Class III vapor retarders shall be installed on the interior side of frame walls when insulating sheathing having a class I or II perm rating is installed on the exterior side of the wall.

    2.    Class I or II vapor retarders shall not be installed on the interior side of either of the following:

    a.    Frame basement walls.

    b.    The below grade portion of any frame wall.

    3.    Construction where  moisture or its freezing will not damage the materials.

History: 1979 AC; 1981 AACS; 1985 AACS; 1995 AACS; 2010 AACS.