Michigan Administrative Code (Last Updated: November 16, 2016) |
![]() |
Department LR. Licensing and Regulatory Affairs |
![]() |
Bureau of Construction Codes |
![]() |
Chapter Michigan Elevator Rules |
Section 408.7033. Drains and sump pumps.
Latest version.
All data is extracted from pdf, click here to view the pdf.
-
Rule 33. Section 2.2.2.4 of the ASME A17.1 code is amended to read as follows:
2.2.2.4 Drains and sump pumps, where provided, shall comply with the Michigan plumbing code, R 408.40701 et seq. and shall be provided with a positive means to prevent water, gases, and odors from entering the hoistway.
Subsoil drains shall not be connected or discharged to elevator pits or sumps.
History: 2003 AACS.