Section 408.30544b. Exterior walls.
All data is extracted from pdf, click here to view the pdf.
-
b. Section R302.5.1 of the code is amended and table R302.1(1) is added to read as follows:
R302.5.1. Opening protection. Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Other openings between the garage and residence shall be equipped with solid wood doors not less than 1 3/8 inches (35 mm) in thickness, solid or honeycomb-core steel doors not less than 1 3/8 inches (35 mm) thick, or 20-minute fire-rated doors.
TABLE R302.1(1) EXTERIOR WALLS
EXTERIOR WALL ELEMENT
MINIMUM FIRE- RESISTANCE RATING
MINIMUM FIRE SEPARATION
DISTANCE
Walls
Fire-resistance rated
1 hour-tested in accordance with ASTM E 119 or UL 263 with exposure from both sides
< 5 feet
Not fire-resistance rated
0 hours
≥ 5 feet
Projections
Not alloweda
NA
< 2 feet
Fire-resistance rated
1 hour on the underside
≥ 2 feet to < 5 feet
Not fire-resistance rated
0 hours
≥ 5 feet
Opening in walls
Not allowed
N/A
< 3 feet
25% maximum of wall
area
0 hours
3 feet
Unlimited
0 hours
5 feet
Penetrations
All
Comply with Section R302.4
< 5 feet
None required
5 feet
For SI: 1 foot = 304.8 mm N/A = Not applicable
a. except as allowed as per Section R302.1 exceptions 3 and 4